We are offering a wide range of machines with bender and cutter in one system gear,for cutting or bending rebar
This board fed 24VAC, manages the working and the check of the limit switches of the machine, moreover through a simple function it allows the storage of three times, maximum, to realize bending sequence.
Operation and warnings:
Bending times settings:
After the on-switch and the machine in 0 position, select by the selector (0-1-2-3) the bending to set, so that both the associated lamp and the running machine lamp will blink. Put in the pin for the desired measure and by the start button make the plate turn till the stop point indicated by the pin, then bring back the plate to the 0 position by the return button. Now pressing the start button you can store the time of the angle carried out, the fast blinking of the lamp that signals the bending marks the successful storage.
Go on in this way for the following bending if necessary. If you do not want to save the operation done bring back the selector to the 0 position.
To zero a bending time previously stored, choose the associated bending and keep the return button pressed for 4 sec., the zero setting of the measure is signalized by a quick on-switch of the three lamps that point out the bending times.
The stored bending times are reset switching off the machine.
When at least one time is stored, bringing back the bending selector to the 0 position the machine carries out the bending in sequence. This function is indicated by the times bending lamps as follows:
-blinking lamp= bending time you are carrying out
-fixed lit lamp= current bending time
In this operation also the start machine lamp is blinking.
Various warning signals:
Warning signals managed by the board are pointed out by a blinking code, pauses on the warning lamp as follows:
1 - fixed on-switch= carter limit switch or cutter intervening
2 - non-stop blinking= warning machine not in zero position
3 - 1 blink, 1 pause= warning breakdown zero limit switch
4 - 2 blinks, 1 pause= warning breakdown reversal limit switch
5 - 3 blinks, 1 pause= warning timeout on-switch command contactor
6 - 4 blinks, 1 pause= warning breakdown command contactor
7 - 5 blinks, 1 pause= warning breakdown reversal or zero limit switch